PROBLEM; WATER WILL NOT "STOP" FLOWING INTO THE HEATING TANK
Follow the same procedure as above but in reverse order. Check the Water Level Probe, Solenoid and level controls.
WATER INLET VALVE TEST (FIGURE 7)
Turn off all power to the brewer. Observe the water level inside the heating tank. If it rises, the water inlet valve is
leaking. Rebuild using Valve kit #99371 or replace inlet valve.
REPLACEMENT KITS
WATER INLET VALVE
DUMP VALVE & BY-PASS VALVE
1 - Coil, 120V - Part #X008A
1 - Coil, 120V Part #CA39A
Coil, 240V - Part #C223A
Coil, 220V Part #CA38A
2 - Valve Kit - Part #99371
2 - Valve Kit - Part #X079A
a) Guide c) Armature
a) Spring c) Plunger
b) Spring d) Diaphragm
b) Diaphragm
PROBLEM: SPRAY-HEAD WILL NOT STOP DRIPPING OR RUNNING
DUMP VALVE TEST (Figure 8)
Turn off all power to the Brewer. If dripping or running continues, replace naive plunger, spring and diaphragm
using Valve Kit #X079A or simply replace with new dump valve.